Skip to Content


Commands LT32

 

Command

Description

Example

PASSWORD,[Old password],[New password]#

Set password to change IP commands.

Default: none. 

Maximum: 8 digits.

PASSWORD,1234# 

 Set the password to 1234

PASSWORD,1234,5555# 

 Password changed from 1234 to 5555

BTPSW,[Old password],[New password]#

Set bluetooth password. 

Default: 1234. 

Maximum: 8 digits. 

BTPSW,1234,5555# 

 Password changed from 1234 to 5555

IP,ip/dns,port,type#

Set main server IP or domain, Port, Communication type, no password

IP,183.16.111.166,8885,1#

     Set the main server IP: 183.16.111.166, Port: 8885, Communication type: TCP

IP,www.vodofo.com,8880,0#

    Set the domain name of the main server: www.vodofo.com, Port: 8880, Communication type: UDP

IP#  Query main server parameters

IP,psw,ip/dns,port,type#

Set main server IP or domain, Port, Communication type, with password.

IP,1234,183.16.111.166,8885,1#

   Set the main server IP:183.16.111.166,Port:8885, Communication type:TCP, Password:1234

IP,1234,www.vodofo.com,8880,0#

    Set the domain name of the main server is :www.vodofo.com,Port:8880,Communication type:UDP, Password:1234

IP#  

 Query main server parameters

IP2,ip/dns,port,type#

Set Secondary server IP or domain, Port, Communication type,No password

IP,183.16.111.166,8885,1#

     Set the secondary server IP: 183.16.111.166, Port: 8885, Communication type: TCP

IP,www.vodofo.com,8880,0#

    Set the domain name of the main server is :www.vodofo.com, Port 8880, Communication type: UDP

IP#  

 Query main server parameters

IP2,psw,ip/dns,port,type#

Set Secondary server IP or domain, Port, Communication type,With password

IP,1234,183.16.111.166,8885,1#

   Set the secondary server IP:183.16.111.166,Port:8885,Communication type:TCP, Password:1234

IP,1234,www.vodofo.com,8880,0#

    Set the domain name of the main server is :www.vodofo.com,Port:8880,Communication type:UDP,Password:1234

IP#  Query main server parameters

APN,apn,user,pswd#

Set APN, Users name, Password

APN,IOT#  

   APN:IOT, no username & password

APN,IOT,internet,internet#

   APN:IOT, Username: internet, Password: internet

APN#   Query

LEVEL,S#

Set vibration sensitivity

S: Sensitivity,1/2/3/4/5 means Highest/High/Medium/Low/Lowest

Default: 2

LEVEL,1# 

  Set the sensitivity as highest

LEVEL#

  Query

HC,T1,T2[,T3]#

TIMER,T1,T2#


Set real-time positioning mode and return interval time

T1:Starting mode interval,  range 5-300s , Default is 15s

T2:Turn off mode interval,range 5-600s, Default is 120s

T3:Sleep mode interval, range 15-600s,Default is 180s

HC,30,90#

  Set upload interval as 30 s while ignition on, set upload interval as 90s while ignition off

HC,30,90,300#

  Set upload interval as 30 s while ignition on, set upload interval as 90s, upload interval while sleep mode as 300s

HC#

  Query

CORNER,A#

Set corner compensation degree. Default:15. Range: 5-180 degrees.

CORNER,15# 

  Set concer compensation degree is 15 degree.

CORNER#

  Query

XM,tttt#

Set the period come to power saving mode under real-time positioning

Unit: minute    Default is 5 minutes


XM,5#   Enter into sleep mode after 5 mins no vibration

XM,0#    Disable auotomoatic sleep function

XM#     Query

IMEI#

ICCID#

Query IMEI/ICCID/IMSI

IMEI#

ICCID#

BLIND,A#

Set bilnd zone compensation switch,A=1 Off;A=0 Open.Default is open

BLIND,1#  

 Turn off Blind zone compensation

BLIND#     

 Query

LOCKACCOFF,A#

Set lock logic, Default: 3.

A=3: Execute only if it has valid GPS signal and speed lower than 15km.

A=2: Command queued. The command is only executed  when ACC changes from off to on with valid GPS signal.

A=1: If ACC is off the command is executed, otherwise the command is queued and executed when ACC changes from on to off.

A=0: Execute always.

LOCKACCOFF,0#  

 Logic 0

LOCKACCOFF#    

 Query

LOCKSPEED,V#

Set lock logic 3 and speed

V:Speed,Range:0-200km/h,Default: 15km/h

LOCKSPEED,30#

 Speed 30

LOCKSPEED#

 Query

WY,<A>[,R,M]#

Displacement Alarm

A: Alarm On/Off,1:Alarm On  0:Alarm Off   Default is off

R: Radius,Dafault is 300m,Value:0, 100-2000m

M: Alarm mode,M=0:Only GPRS,M=1:SMS+GPRS

WY,1,500,1#     Alarm on,Radius 500m,Notice:GPRS+SMS

WY,1#               Alarm On

WY,0#               Alarm off

WY#

ZD,<A>[,M]#

Vibration Alarm

A=1:Alarm On  A=0:Alarm Off    Default is Off

M: Mode,M=0:Only GPRS,M=1:SMS+GPRS

ZD,1,1#,   Alarm on,mode:GPRS+SMS

ZD,0#           Alarm off

ZD#

ZDT,<AT>,<DT>#

Vibration alarm time setting

AT: Vibration alarm delay time, unit: minutes; Rangle:1-10,default is 3 minutes

DT: Vibration alarm fortification time, unit: minutes; Range is 1-20 minutes, default is 10 minutes

ZDT,2,5#   Vibration alarm delay time: 2 minutes; vibration alarm fortification time: 5 minutes

ZDT#

UTC,tttt#

Set time zone,Unit:min,Default:UTC+8:00

UTC,330#  Time zone at UTC+5:30

UTC,-210#   Time zone at UTC-3:30

UTC#

SPEED,V,T#

Set overspeed and duration

V: Overspeed threshold, value range: 0-255km/h, Default is 0:close overspeed

T: Overspeed duration, value range: >=5s, the default is 5s

SPEED,50,5#  Set the overspeed threshold to 50km/h, and it will alarm when lasted 5s

SPEED#    Query

VACC,v#

Set ACC detection mode

v, voltage threshold, unit 0.1V

v=0, Detect ACC state via the ACC signal line, as defaulted.

v=131, Detect ACC state  by vibration and voltage, and the voltage threshold is 13.1V

VACC,0# : Detect the ACC status through the ACC signal line

VACC,131# Detect ACC status by vibration and voltage, the voltage threshold is 13.1V

VACC#    Query

UPGRADE,IP/Domain,Port,Version#

OTA,IP/Domain,Port,Version#

Upgrade

UPGRADE,119.23.233.52,7771,MT02S-4.12#

OTA,www.365qczx.com,7771,MT02S-4.12#

UPGRADE,0#  Exit

UPGRADE#    Query

COLLISION,N#

Set collision level

N Value Range:0-3000

Default is 0,alarm off

COLLISION,1000#  Collision level is 1000

COLLISION#      Query

TURNOVER,A#

Set the turnover alarm, unit: 0.1g

N is value range: 0,5-80g

The default 0 is to turn off the alarm

TURNOVER,10#  Send alarm when aceleration speed more than 1g when power off over 5s 

TURNOVER#     Query

DRIVING,A,V1,V2,T#

Driving Behavior Detection

A:Sharp cornering,Range:0-180,Default is 0,turn off the alarm

V1:Accelerate,Range:0-255,Default is 0,turn off the alarm

V2:Decelerate,Range:0-255,Default is 0,turn off the alarm

T:Acceleration and deceleration detection time,Range:1-30,Default is 4s

DRIVING,15,30,50,4#

When the speed is over 60km/h, thecornerning over 15° for 2 seconds, which is considered as a sharp turn

  Accelerate: Speed has increased by 30km/h in 4 seconds

  Decelerate:Speed  decreased by 50km/h within 4 seconds

DRIVING# Query

BLETYPE,A#

Set BLE function:

A=0 WIFI on,BLE Off

A=1 Open BLE sever,parameter configuration via mobile,as defaulted.

A=2 Open BLE client,connecting accessories

A=3 Open BLE server,BLE passthrough function

BLETYPE,2#  Open BLE Client

BLETYPE#  Query

TIREALARM,P1,P2,T#

Set Tire pressure alarm

P1: high tire pressure alam, unit: 0.1bar, range: 0-255, default 31, P1=0,alarm off.

P2: Low tire pressure alarm , unit: 0.1bar, range: 0-255, default 20,P2=0,alarm off.

        P1 must be bigger than P2

T: high temperature alarm , unit: 1℃, range:0-255, default is 80, T=0,alarm off

TIREALARM,41,22,50#

High tire pressure alarm at 4.1,low tire pressure alarm at 2.2,high temper alarm at 50℃

TIREALARM#   Query

   

TIRETIMEOUT,T#

Set the Bluetooth tire pressure sensor timeout 

unit: minutes, Range: 5-120,Default is 60, means sensor has not been received for 60 minutes, and tire pressure data is cleared.

TIRETIMEOUT,10#

TIRETIMEOUT#   Query

TIREINFOR,N,ID_1,MAC_1,..ID_N,MAC_N#

Binding sensor and wheel position

N: Tires number, Range is 0-8; 0 :Unbind (default),BLETYPE, A# A=1 automatically. N>0, BLETYPE, A# A=2 automatically.

ID_1-ID_N: Tire position number,Range: 1-8

MAC_1-MAC_N: The MAC address of tire position number, the format is AABBCCDEEFF

TIREINFOR,2,1,04B3ECD00A06,2,04B3ECD00A0E#

TIREINFOR,0#  Unbind

TIREINFOR#   Query

IBEACON,uuid,major,minor,rssi#

UUID:32bytes,default is 00000000000000000000000000000000

major:Ibeacon group code,default is 0,range0-65535

minor:Ibeacon code,default is 0,range:0-65535


IBEACON,0000ffa06da44e50a375bade13be6daa,1,0,-59#

IBEACON,D#

Delete Ibeacon

IBEACON,D#